Hersey Meters
Home Profile Products Hersey Meters School Seminars Career Opportunities Contact Hersey
Model DC
Model EDC III
Model EDC IV

For further details of the Model EDC IV Spring Loaded Detector Check Valves and Parts please view the PDFs below.
For more information about PDFs please see our PDF advice page.

Download Model EDC IV Catalogue (280 KB)

 

Download Model EDC IV Parts Guide (200 KB)

 

For the latest information about updates and improvements to Hersey Meters's product range.

View Detector Checks Product Bulletins
 


Model EDC IV Spring Loaded Detector Check Valves
 
  Model EDC IV Spring Loaded Detector Check Valves

APPLICATIONS: For installation in commercial fire lines, or any water supply system to detect leakage or unauthorized use. Designed for horizontal or vertical installation.

CONFORMANCE TO STANDARDS: UL, ULC listed; FM approved.

DESCRIPTION: HERSEY Model EDC IV Check Valves consist of a spring loaded main check valve (available with optional trim kit and bypass meter). The Model EDC IV prevents water from re-entering the potable water system, while detecting leaks in the fire sprinkler system or unauthorized use of sprinkler system water. All operating parts of the spring and clapper mechanism are at-tached to the cover for easy removal and maintenance. For safety, full spring tension is not achieved until the cover is bolted to the body. Spring mechanism provides for low headloss during fire conditions.

The optional bypass is comprised of a shutoff valve, swing check, and a Hersey Model MVR magnetic turbine meter, or a Hersey Model 400/500 IIS positive displacement meter.

Solid state remote reading systems are available for all meters offered with the Model EDC IV (See Reading Systems Section).

OPERATION: With the mainline valve held closed by the spring, any low flow will be directed through the bypass and measured by the bypass meter. When the pressure loss through the bypass is approximately 2.0 psi, the mainline valve opens automatically, allowing unrestricted flow. The mainline valve and check on the bypass prevent loss of water from the system. Closing the inlet shutoff valve permits in-line servicing of the bypass meter while the mainline remains in service.

END CONNECTIONS: Flange x Flange in all sizes.

Model Designation EDC IV

Sizes 3", 4", 6", 8" 10"

Maximun Working Pressure 175 PSIG

Hydrostatic Test Presure 350 PSIG

Temperature Range 33F to 110F

Standards Underwriters Laboratories (UL) Listed;
Underwriters Laboratories of Canada (ULC) Listed;
Factory Mutual (FM) approved.

Valve Body Red enamel on cast iron or optional fusion bonded epoxy coating on cast iron.

Clapper Seat Rubber clapper on a bronze seat

Bypass Tapping 4"-8" .....3/4" Tap
10" .....1-1/2" Tap